BHQDL - WINDOW-SAN AEROSOL

Product Identification

Product ID:WINDOW-SAN AEROSOL
MSDS Date:09/18/1987
FSC:7930
NIIN:00D002602
MSDS Number: BHQDL

Responsible Party
HUNTINGTON LABORATORIES INC
970 E TIPTON ST
HUNTINGTON, IN 46750-1611
US

Emergency Phone: 219-356-8100

Info Phone: 219-356-8100

Preparer: CLEM L.HARRIS

Cage: 29800

Contractor
HUNTINGTON LABORATORIES INC
HUNTINGTON, IN 46750-1611 US

Telephone: 219-356-8100

Cage: 29800

Ingredients

ISOBUTANE

CAS: 75-28-5

RTECS: TZ4300000

Fraction By Weight: 60-80%


ISOPROPYL ALCOHOL (SARA III)

CAS: 67-63-0

RTECS: NT8050000

Fraction By Weight: 0-10%

OSHA PEL 400 PPM/500 STEL

ACGIH TLV: 400 PPM/500STEL;9192


AMMONIA (SARA III)

CAS: 7664-41-7

RTECS: BO0875000

Fraction By Weight: 0-109%

OSHA PEL 50 PPM

ACGIH TLV: 25 PPM/35 STEL; 9293

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:IRRITATION OF
EYES,SKIN,RESPIRATORY OR G.I.TRACTS;CNS EFFECTS LIKE
HEADACHE,DIZZINESS AND NAUSEA POSSIBLE.MAY BE HARMFUL IF
SWALLOWED.CHRONIC:NO DATA AVAILABLE.
Explanation of Carcinogenicity:DATA PER MSDS
Effects of Overexposure:SEE HEALTH HAZARDS DATA.
Medical Cond Aggravated by Exposure:PERSONS WITH A HISTORY OF AILMENTS
OR WITH A PRE-EXISTING DISEASE INVOLVING THE EYES, SKIN, OR
RESPIRATORY TRACT MAY BE AT INCREASED RISK FROM EXPOSURE.

First Aid

First Aid:INHALATION:REMOVE TO FRESH AIR. RESUSCITATE IF NOT BREATHING.
GET MEDICAL ATTENTION. EYES:IMMEDIATELY FLUSH WITH PLENTY OF WATER
FOR 15 MINUTES HOLDING EYELIDS OPEN. GET MEDICAL ATTENTION.
SKIN:REMOVE CONTAMINATED CLOTHING. WASH WITH SOAP AND WATER. IF
IRRITATION PERSISTS, GET MEDICAL ADVICE. INGESTION:DO NOT INDUCE
VOMITING. GIVE NOTHING BY MOUTH IF UNCONSCIOUS. GET IMMEDIATE
MEDICAL ATTENTION.

Fire Fighting

Flash Point Method:TOC
Flash Point:70.0F,21.1C
Extinguishing Media:USE CARBON DIOXIDE, FOAM, DRY CHEMICAL, OR WATER
FOG.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA &
FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE. USE WATER
SPRAY TO COOL NEARBY CONTAINERS EXPOSED TO FIRE.
Unusual Fire/Explosion Hazard:NONE SPECIFIED

Accidental Release

Spill Release Procedures:USE PROPER PERSONAL PROTECTION;CONTAIN FREE
MATERIAL IF POSSIBLE;USE SUITABLE INERT ABSORBENT MATERIAL AND
RECOVER FOR PROPER DISPOSAL IN AN APPROVED CONTAINER.
Neutralizing Agent:NOT APPLICABLE.

Handling

Handling and Storage Precautions:STORE IN A COOL, DRY, WELL VENTILATED
AREA. KEEP CONTAINERS TIGHTLY CLOSED WHEN NOT IN USE.DO NOT BREATHE
VAPORS/MIST.KEEP AWAY FROM CHILDREN.
Other Precautions:DO NOT TAKE INTERNALLY. DO NOT BREATHE MIST. AVOID
PROLONGED OR REPEATED BREATHING OF VAPOR. AVOID CONTACT WITH EYES.
USE WITH ADEQUATE VENTILATION. WASH THOROUGHLY AFTER HANDLING.

Exposure Controls

Respiratory Protection:NORMALLY NOT REQUIRED;USE NIOSH/MSHA APPROVED
RESPIRATOR AS REQUIRED IF ABOVE PEL/TLV.
Ventilation:NORMAL ROOM VENTILATION OR LOCAL/GENERAL TO MAINTAIN
PEL/TLV.
Protective Gloves:NEOPRENE/ NATURAL RUBBER SUGGESTED
Eye Protection:SAFETY GOGGLES WITH OPTIONAL FACE SHIELD
Other Protective Equipment:EYE WASH STATION AND SAFETY SHOWER,WORK
CLOTHING AND APRON AS REQUIRED.
Work Hygienic Practices:OBSERVE GOOD PERSONAL HYGIENE PRACTICES AND
RECOMMENDED PROCEDURES. DO NOT WEAR CONTAMINATED CLOTHING OR
FOOTWEAR.
Supplemental Safety and Health
AVOID PROLONGED OR REPEATED EXPOSURE. DO NOT GET ON SKIN OR IN EYES. DO
NOT BREATHE VAPORS OR MISTS.

Chemical Properties

HCC:F3
Boiling Pt:B.P. Text:190F,88C
Spec Gravity:0.975
Evaporation Rate & Reference:1.2 NO REF
Solubility in Water:100%
Appearance and Odor:AEROSOL MIST PERFUME AND AMMONIA ODOR

Stability

Stability Indicator/Materials to Avoid:YES
NOT SPECIFED
Stability Condition to Avoid:HIGH TEMPERATURES
Hazardous Decomposition Products:AMMONIA VAPORS

Disposal

Waste Disposal Methods:CONSULT LOCAL AUTHORITIES.DISPOSAL MUST BE MADE
IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL LAWS AND
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.